Enter the characters you see below
Sorry, we just need to make sure you're not a robot. For best results, please make sure your browser is accepting cookies.
Type the characters you see in this image:
Try different image
Conditions of Use Privacy Policy
© 1996-2014, Amazon.com, Inc. or its affiliates
First Alert SCO500 Combination Smoke and Carbon Monoxide Alarm - Use Manual - Use Guide PDF.
Documents: Go to donwload!
User Manual
- Owner's manual - (English)
Other Documents
- Product Documentation - (English)
User Manual for First Alert SCO500
Table of Contents
- Introduction
- Wireless Operation
- Fire Safety Tips
- Basic Safety Information
- Step By Step Guide to Programming This Alarm
- Adding and Linking Additional ONELINK® Alarms
- What You Will See and Hear With This Alarm
- Installation
- Where to Install This Alarm
- Where This Alarm Should NOT Be Installed
- How to Install This Alarm
- Optional Locking Features
- If Your Smoke/CO Alarm Sounds
- What To Do First–Identify The Type Of Alarm Signal
- If the CO Alarm Sounds
- If the Smoke Alarm Sounds
- Using the Silence Features
- Latching Features
- Weekly Testing
- Regular Maintenance
- What You Need To Know About CO
- What is CO?
- Symptoms of CO Poisoning
- Finding the Source of CO After an Alarm
- Potential Sources of CO in the Home
- How Can I Protect My Family From CO Poisoning?
- Regulatory Information For Smoke/CO Alarms
- Regulatory Information for CO Alarms
- Regulatory Information for Smoke Alarms
- Recommended Locations for Smoke Alarms
- About Smoke Alarms
- Special Compliance Considerations
- General Limitations Of Smoke/CO Alarms
- Troubleshooting Guide
- Limited Warranty
HOW TO INSTALL THIS ALARM
For quick installation instructions see the “Quick and Easy Guide to Programming Your ONELINK® Alarm and Using the Optional Features”.
- 1. Hold the mounting bracket against the ceiling (or wall) so the vertical mounting slot is aligned in the 12 o’clock position and trace around the inside of the mounting slots (vertical and horizontal mounting).
- 2. Put the unit where it won’t get covered with dust when you drill the mounting holes.
- 3. Using a 3/16” (5 mm) drill bit, drill a hole through the center of the oval outlines you traced.
- 4. Insert the plastic screw anchors (in the plastic bag with screws) into the holes. Tap the screw anchors gently with a hammer, if necessary, until they are flush with the ceiling or wall.
- 5. Line the mounting bracket up over the plastic screw anchors.
- 6. Screw the mounting bracket to the ceiling or wall through the mounting slots using the two screws provided.
- 7. Attach the Smoke/CO Alarm to the mounting bracket. Line up the guides on the alarm’s base with the guides on the mounting bracket. When guides are lined up, turn the base clockwise (right) until it snaps into place.
NOTE: Once the Alarm is snapped onto the mounting bracket, you can rotate the Alarm to adjust the alignment.
- 8. Test the Smoke/CO Alarm. See “Weekly Testing” for details.
IMPORTANT : This combination Smoke/CO Alarm was designed to be mounted on the ceiling or wall. It is not a tabletop device. You must install this device on the ceiling or wall as outlined below. Read “Where To Install This Alarm” before starting.
IMPORTANT : If you want to lock the battery compartment, or lock the Smoke/CO Alarm to the mounting bracket, please read the “Optional Locking Features” section in the “Quick and Easy Guide to Programming Your ONELINK® Alarm and Using the Optional Features” attachment before you begin installation.
CAUTION : • Do not install this unit over an electrical junction box. Air currents around junction boxes can prevent smoke from reaching the sensing chamber and prevent the unit from alarming. Only AC powered units are intended for installation over junction boxes.
Newest Added: BRK SC9120B-3 SC7010B PRC710 SCO5CN SC7010BV
Tags: First Alert Carbon Monoxide Detectors, First Alert Co 710, First Alert SCO500, First Alert, First Alert Smoke And Carbon Monoxide Detector, First Alert Smoke Alarm